While ensuring health and safety measures, Hanna Instruments is open for business as usual. The HI is a high accuracy benchtop turbidity meter. Thank you for your interest in our products. A representative will contact you within the next 2 hours.

The HI Precision ISO Turbidity Benchtop Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges.

The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.

Turbidity ranges for each mode are 0. Calibration - The HI has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. Calibration points can be modified if user-prepared standards are used. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life. Data includes calibration points, date, and time.

Data Logging - Up to measurements can be stored in the internal memory and recalled at any time. Tutorial Mode - The unique tutorial mode provides additional information to help the user during measurements. When enabled, the instrument displays explanations and a confirmation button when a preparation or other operation has to be performed. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.

All messages are in plain text making them easy to read. Turbidity is one of the most important parameters used to determine the quality of drinking water. Once considered as a mostly aesthetic characteristic of drinking water, significant evidence exists that controlling turbidity is a competent safeguard against pathogens.

In natural water, turbidity measurements are taken to gauge general water quality and its compatibility in applications involving aquatic organisms. The monitoring and treatment or wastewater was once solely based on the control of turbidity.

Currently, the measurement of turbidity at the end of the wastewater treatment process is necessary to verify that the values are within regulatory standards.

Turbidity of water is an optical property that causes light to be scattered and absorbed, rather than transmitted. The scattering of light that passes through a liquid is primarily caused by the suspended solids present. The higher the turbidity, the greater the amount of scattered light. Even a very pure liquid will scatter light to a certain degree, as no solution will have zero turbidity. The ISO standard for turbidity measurement uses infrared wavelength of light that is outside the visible spectrum.

The EPA method uses a tungsten lamp that produces light that contains all of the visible wavelengths of light that we see as white. A solution that is colored will be adsorbed by a complementary wavelength of light which will affect the turbidity reading.

Since the ISO method is outside the visible wavelength of light the color in the sample does not interfere with the measurement. The USEPA prefers the tungsten lamp since it provides for better accuracy at low ranges and drinking water should not be colored.

The requirements of an optical turbidity meter according to ISO are dependent on the measurement range. The measurement of diffuse radiation is typically for low range turbidity measurements i. The measurement of attenuation of radiant flux is for highly turbid samples i.

The design criteria for each method are:. The light beam that passes through the sample is scattered in all directions. Which detectors are used are based on the measurement mode. In FAU mode the turbidity is calculated from the signal that reaches the transmitted light detector. In the ratio turbidimeter range, the microprocessor of the instrument calculates the NTU value from both the scattered and transmitted light detectors. The lower detection limit of a turbidimeter is determined by stray light that is detected by the sensors but not caused by light scattering from suspended particles.

The optical system of the HI is designed to have very low stray light, providing highly accurate results for low turbidity samples. These standards are used for calibration and performance verification of the turbidity meter. Ratio and non-ratio turbidity modes USB for data transfer.

Add to Cart. Request a Quote Thank you for your interest in our products. The design criteria for each method are: Measurement of diffuse radiation for water with low turbidity 0 FNU to 40 FNU The wavelength of the incident radiation shall be nm The spectral bandwidth of the incident radiation shall be less than or equal to 60 nm There shall be no divergence from parallelism of the incident radiation and any convergence shall not exceed 1.

The aperture angle should be between 20o and 30o in the water sample. Measurement of attenuation of radiant flux for highly turbidity 40 FAU to FAU The wavelength of the incident radiation shall be nm The spectral bandwidth of the incident radiation shall be less than or equal to 60 nm There shall be no divergence from parallelism of the incident radiation and any convergence shall not exceed 2. The aperture angle should be between 10o and 20o in the water sample.

Principal of Operation The light beam that passes through the sample is scattered in all directions. Don't Forget! Add your reagents or accessories now to save time and money later! Warranty 2 years.

ASSIMIL ALEMAN SIN ESFUERZO DESCARGAR PDF

Measuring Turbidity, TSS, and Water Clarity

Superseded By: ISO Prices subject to change without notice. About Us. Contact Us. Sign In. Standards Store. Purchase History.

BAREME IRG SALAIRE ALGERIE PDF

ISO 7027 Compliant Benchtop Turbidity Meter

Turbidity, as an optical property of water, is one of the more difficult parameters to measure. How murky or opaque water is can be a subjective measurement 1. Based on the measurement method, different units have been defined to standardize turbidity levels and allow comparisons. Today, there are three modern methods for measuring turbidity, and two for measuring total suspended solids. These methods have expanded the range and accuracy of turbidity measurements from basic object visibility tests and historical visual extinction methods 2. However, each method has its advantages and limitations.